The fault name
Module Fault
Fault information
Troubleshooting and illustration
1.Turn on the switch.
2.The CN17 is securely connected.
3.Check that the module address is correct.
4.Key check.
The fault name
Over temperature
Fault information
Troubleshooting and illustration
1.The temperature is over 90 degrees.
2.Wait for the temperature to drop before recharging at restart
The fault name
Lightning protection fault
Fault information
Troubleshooting and illustration
Check whether the two wires are secure.
2.Insert in the correct position.
The fault name
The address of the meter is wrong
Fault information
Troubleshooting and illustration
1.Enter the correct 16-bit meter address.
2.Add 1 to the address at the end of the B gun meter.
The fault name
Door opened
Fault information
Troubleshooting and illustration
Close the front and back door
The fault name
Emergency stop press
Fault information
Troubleshooting and illustration
1.Find the red emergency stop button.
2.The emergency stop fault is removed by clockwise rotation.
The fault name
Door opened
Fault code
118
Number of flashing red lights
14
Troubleshooting and illustration
1. This function is for charging piles with door switch.
2. Close the charging pile door and the fault will be removed.
3. If the above operation fails, replace the micro switch.
The fault name
PEN Fault
Fault code
116
Number of flashing red lights
12
Troubleshooting and illustration
Check whether the inlet line N wire is loose, and fix it if it is loose
2. There should be no voltage between PE and N.
3. If there is a voltage, the null line is charged.
4. Check the incoming line until the voltage is normal.